Homepage
The RCP22 plug-in socket receiver for heating control regulates a connected heating unit based on the switching signals received from the Easywave temperature sensor ST01.

In doing so, the RCP22 determines by itself whether adjustment is needed either via the ON/OFF mode or via pulse-width modulation (PWM).

In addition, up to 16 window contacts *) (OFF/ON) can be programmed into the receiver in order to stop the heating automatically when a window is opened.

If the radio connection to the thermostat is interrupted, the RCP22 goes into emergency mode after 10 hours, thus preventing the room from cooling down.

RCP22E5001A01-K
Technical specifications
Coding Easywave
1x ST01 and maximum 16x RTS16 or RTS26 *) can be programmed.
Frequency 868,30 MHz
Channels 1
Power supply 230V AC, 50Hz
Power consumption 0.2 W standby
0.7 W relay switched (without load)
Operating modes temperature control
PWM
ON/OFF
Output protective contact plug (D/A/NL/S/N)
Maximum contact load 16A / 230V AC
Operating temperature -10 °C to +35 °C
Dimensions 71,4 x 71,4 x 75,5 mm
Color white similar to RAL 9003
Plug system
*) The following window contacts are compatible:
RTS16E5001B02 OFF/ON
RTS16E5001-02 STATUS, OFF/ON
RTS16E5001A02 STATUS, OFF/ON
RTS26E5001B03 OFF/ON
RTS26E5001A03 STATUS, OFF/ON
Scope of delivery
  • Plug-in socket receiver
  • Operating manual
Models
Product numbers Description Plug system
RCP22E5001A01-K Plug-in socket receiver heating, Easywave, 230V, 1x normally open, pot.-loaded, D/A/NL/S/N, white